Slide background
Slide background

S2 plus

System for HDI and substrate products

 

S2 16cf ds frontThe S-line is characterized by an outstanding test head technology. Linear motor drives in combination with ceramic air bearing gives the S2-8 plus and S2-16 plus the highest speed and accuracy. The testers are equipped with a dual shuttle system. One shuttle can be unload and load while the board in the second shuttle is tested, maximizing machine utilization.

Key Features

  • double shuttle system for fast loading and unloading of boards
  • 15 µm pad size and 30 µm pitch8 test heads
  • max. test area 610 mm x 310 mm (24.0″ x 12.2″)
  • cameras with 3 µm resolution per pixel

Mechanics

  • Max. Panelsize: 610 x 330mm (24" x 13.0")
  • Min Panelsize: 10 x 10mm (0.4" x 0.4")
  • Test area: 610 x 310mm (24" x 12.2" )
  • Board thickness: up to 8mm (0.32")
  • 8 Test heads (4 top / 4 bottom)
  • 4 Camera's (2 top / 2 bottom)
  • Smallest Pad: 15µm * special setup
  • Smallest Pitch: 30µm
  • Resolution measurement system: ± 0.1µm (± 0.004 mil)
  • Repeatable accuracy ± 2µm (± 0.08 mil)
  • Soft Touch Probes pressure 5g to 15g
  • Standard Probes pressure 10g to 100g

Electronics

  • Continuity test: 1Ω - 10 kΩ
  • Capacitance test: 10fF to 1000µF
  • Low voltage range: 100mV to 10V
  • Isolation test:
  • up to 25MΩ (FM) 
  • up to 10GΩ (Ohmic)
  • MicroShort Detection®
  • Test voltage • up to 1000V

Options

  • 4-wire Kelvin measurement with max. 300mA test current
  • 0.1mΩ to 300kΩ - Tolerance ± 2%, min. ± 0.025mΩ
  • with Kelvin probes contact pressure 0.2g to 5g
  • Smallest pad: 50µm ( 2.0 mil)*
  • Smallest pitch: 80µm ( 3.2 mil)
    * with Kelvin probe fine adjustment

Embedded Component test

  • R 0.5Ω - 10MΩ - Tolerance ± 0.5 %, min. ± 0.5Ω
  • > 10MΩ - 50MΩ - Tolerance ± 2 % 
  • C 0.1pF 100µF - Tolerance ± 2 %, min. ± 0.03pF
  • L 0.2µH to 5mH - Tolerance ± 3 %, min. ± 0.1µH
  • Diode/Varistor
    UR reverse voltage
    UBR breakdown voltage up to 10V
  • Pneumatic clamping with supporting table for flexible boards
  • Retest of faultfiles from external grid test systems on inquiry
  • Repair software with barcode support

General connections

  • Data input format: IPC-D-356A
  • Network connection: Ethernet, TCP/IP
  • Power Supply: 3x 400V, 50Hz (3x 208V, 60Hz), 1200VA
  • Compressed air: 8 bar/115psi filtered
  • Temperature: 18°C t0 24°C
  • Relative humidity: 40% to 60%
  • Machine weight: 1530kg


All information subject to change without notice!