Adeon Technologies BV
Weidehek 26 
4824AS Breda
The Netherlands
Phone: +31 (0)76-5410008 
Fax: +31 (0)76-5425059 

E-mail us
 
   
  Mechanics 
Basic unit with 8 test probes (4 top, 4 bottom) 
Variable board fi xing system, multi board test 
Max. board size (X x Y) 650 x 475 mm / 25.6” x 18.7” 
Test area 520 x 400 mm / 20.4” x 15.7” 
Board thickness up to 7 mm 
Smallest pad 75 ìm / 3.0 mil 
Smallest pitch 150 ìm / 6.0 mil 
System accuracy ± 20 ìm / ± 0.8 mil 
Repeatable accuracy ± 10 ìm / ± 0.4 mil 
Rigid probes 10 to 100 g 
 
Electronics 
Continuity test 1 Ù to 10 k Ù 
Isolation test up to 25 M Ù (FM), 
up to 2 G Ù (ohmic) 
Test voltage up to 250 V 

Options 
• HV Test voltage up to 500 V 
• Embedded components test:  

Measurement Tolerance 
R 1 Ù to 50 M Ù ± (0.5 Ù ± 0.5 %) 10 M Ù 
C 0.1 pF to 100 ìF ± (0.03 pF ± 2 %) 
L 0.2 ìH to 5000 ìH ± (0.1 ìH ± 2 %) 

• Vacuum box for single-sided test of inner layers and fl exible boards, 
  fl ip test for double sided boards 
• Retest of fault fi les from grid test systems with barcode support 
• Repair software with barcode support 

Camera System 
2 cameras for optical scanning of top and bottom side 
Resolution from 5 ìm / pixel 

Data Input Format IPC-D-356A 
Network Connection Ethernet, TCP / IP 
Power Supply 230 V, 50 Hz (115 V, 60 Hz), 1800 VA 
Compressed Air not required 
Temperature 18 °C to 27 °C / 66 °F to 81 °F, ± 3 K 
Relative Humidity 40 % to 60 % 
Machine Weight 1200 kg (2645 lb) 

Atg-a1.pdf (pdf, 501 KB)

Request information about this product