E-mail us
 |
|
|
 |
|
|
 |
 |
 |
 |
 |
 |
 |
| |
    |
|
|
 |
|
| |
Mechanics Fully automatic loading, test and stacker system for different board sizes in succession without stopping test procedure Basic unit with 8 test probes (4 top, 4 bottom) Options • 4-wire measurement: 1 m Ω to 1 kΩ (± 0.1 m Ω ± 2 %) Blades, 5 to 15 g Kelvin, 5 to 15 g • LaTest® open detection with LaTest®-blade probes: 50 to 100 g • Embedded components test: Measurement Tolerance R 1 Ω to 50 M Ω ± (0.5 Ω ± 0.5 %) 10 M Ω C 0.1 pF to 100 ìF ± (0.03 pF ± 2 %) L 0.2 μH to 5000 μH ± (0.1 μH ± 2 %)
• Marking System – Label Printer or Inkjet Printer • Retest of fault fi les from grid test systems with barcode support • Label printer with barcode support • Repair software • Glass calibration board
Camera System 4 cameras (640 x 480 pixel) for rapid optical scanning of top and bottom side Resolution from 5 μm / pixel Data Input Format IPC-D-356A Network Connection Ethernet, TCP / IP Power Supply 3 x 400 V, 50 Hz (3 x 208 V, 60 Hz),2500 VA Power Supply Vacuum Pump 3 x 400 V, 50 Hz (3 x 208 V, 60 Hz) for Vacuum Table 3000 VA Compressed Air 6 bar / 90 psi, filtered, constant air quantity Temperature 18 °C to 27 °C / 66 °F to 81 °F, ± 3 K Relative Humidity 40 % to 60 % Machine Weight 1850 kg